Only applicable to GP-Probe TGE2
GP-Probe TGE2 can operate with or without the GP-Blocker connected.
The device supports up to 4 connected GP-Blocker.
Learn how to configure the GP-Blocker here.
Error codes:
- 472 - GP-Blocker 1
- 473 - GP-Blocker 2
- 474 - GP-Blocker 3
- 475 - GP-Blocker 4
Reason 1: GP-Blocker is enabled in the configuration panel of GP-Probe TGE2, but the GP-Blocker is not connected.
Solution 1: If you do not intend to use GP-Blocker, disable it in the GP-Probe TGE2 configuration panel:
Reason 2: When using multiple GP-Blockers, the GP-Blocker IDs are not correctly configured.
Solution 2: The GP-Blocker IDs must be unique. Learn how to configure the GP-Blocker here.
Reason 3: GP-Blocker hardware failure. GP-Blocker has its own fault detection system. When it receives a command from the GP-Probe TGE2, the blocker executes the command and sends an error code.