If you have forgotten the password to access the web configuration panel or if you need to switch the device to use a static IP address, you can reset the probe to the factory default settings.


When resetting, the following settings will be restored:

  • IP type: static
  • IP: 192.168.0.120
  • username/password: user/user, admin/admin


Access settings for GP-Cloud and LUA script will not be affected.


To reset, you should:

  • Disconnect the device from the power source
  • Press and hold the button on the front panel
  • Connect the power supply 
  • Wait five seconds until the message "Are you sure you want to reset settings?" appears on the screen:


  • Release the button
  • Press and hold the button again for five seconds.